Hospitals & clinics · Plan around critical care functions · Research checked 2026-09-05
A healthcare water project must be led by the facility’s actual services and the consequences of interruption. Drinking, hand hygiene, cleaning, sanitation and specialist clinical uses cannot be treated as interchangeable. The clinical, infection-prevention and estates teams should define the requirements before a borehole, treatment package or reserve tank is selected. This guide helps organise that brief and the evidence needed for procurement and handover.
Your first decision. Identify critical water functions and their approved requirements with the facility team before specifying capacity or treatment.
Describe the services that depend on water
WHO and UNICEF’s WASH FIT provides a risk-based improvement framework connecting water with hygiene, sanitation, environmental cleaning and facility management. It supports organised assessment and corrective action; it does not certify a borehole or prescribe every specialist clinical-water quality. WASH FIT, second edition.
Inventory the facility’s services and identify their responsible clinical leads. Record operating hours, critical outlets, current interruptions and existing backup arrangements. Ask each lead to define the acceptable service conditions and escalation route. Keep ordinary potable supply separate from dialysis, sterilisation, laboratory or other specialist requirements that need their own competent specification.
Do not derive a clinical design from bed count alone. Outpatient activity, maternity services, cleaning arrangements, kitchens and staff accommodation can change the demand and continuity brief. Where information is incomplete, document the gap and the person responsible for resolving it before equipment procurement.
Assess the whole route from source to point of use
Kenya’s November 2025 Basic Design Report presents conceptual WASH infrastructure designs for Level 2 dispensaries and Level 3 health centres. It considers local conditions and long-term functionality. Its scope should not be expanded into a universal layout for referral hospitals. Infrastructure Design and Construction Quality for WASH in Health Care Facilities: Basic Design Report.
Map source protection, treatment, storage, distribution and sampling points. Include maintenance access and the ability to isolate work without uncontrolled interruption to critical areas. Ask the responsible specialists to identify applicable criteria and verification methods. A satisfactory raw-water sample alone cannot demonstrate that the building system consistently delivers the required quality at all relevant outlets.
Use the hydrogeological and construction evidence to assess the source, then use pumping-test interpretation to inform the operating recommendation. Water chemistry and microbiological assessment guide the appropriate treatment investigation. Do not assume that drilling deeper makes water sterile or suitable for clinical equipment.
Plan continuity and maintenance together
Define a contingency for source, pump, power and treatment failures with the facility team. Assess usable storage against the critical functions and the agreed response time. Identify the quality and operational requirements of any backup supply. The plan should say who authorises a changeover, what verification is required and how staff are informed.
Coordinate work around clinical operations and infection-prevention arrangements. A maintenance plan should address tank access, treatment servicing, electrical isolation and safe restoration. Avoid accepting a single unsupported statement that the system has “backup”; specify what fails, what remains available and what must be checked before normal operation resumes.
Assign monitoring and corrective action to named roles
Agree which staff review operating readings and laboratory results, and how exceptions are escalated. Keep logs understandable to the next shift and retain the underlying technical records. A record of corrective action should show the issue, response, verification and responsible person. Monitoring without a response process does not resolve a service failure.
Include staff training and recurrent costs in procurement. Ask for equipment documentation, compatible replacement parts and the maintenance tasks that require specialist attendance. The facility should review the water plan when services expand or workflows change. A maternity extension, for example, needs a fresh clinical and estates assessment even when the borehole itself remains unchanged.
A dispensary adding maternity services
Illustrative planning example. This hypothetical expansion illustrates a decision process. It supplies no clinical demand norm, reserve duration or treatment specification.
| Review area | Question for the facility team | Evidence before acceptance |
|---|---|---|
| Critical access | Which new functions require continuous water? | Approved service and outlet requirements |
| Contingency | What happens during pump or treatment failure? | Documented, assessed backup procedure |
| Distribution | Can work be isolated and safely restored? | Reviewed network and maintenance plan |
| Verification | Who confirms readiness for the intended uses? | Facility-approved test and acceptance records |
The outcome may involve changes to storage, distribution, monitoring or backup as well as the source. The clinical and technical teams must determine the actual requirements. The conceptual Level 2/3 report is useful context, but it does not remove the need for a facility-specific design and review.
A quotation that matches this project
Request a complete scope reviewed by the facility’s responsible professionals. Keep ordinary supply works and specialist clinical-water packages distinct, with clear interfaces and acceptance responsibilities.
| Budget item | What changes the scope | What to ask for |
|---|---|---|
| Source and protection | Site conditions and required operating evidence | Survey, completion records and interpreted testing |
| Quality and distribution | Approved uses, sampling and maintenance access | Specialist-reviewed criteria and verification plan |
| Continuity | Critical functions and failure scenarios | Assessed storage, backup and changeover arrangements |
| Ongoing control | Staff responsibilities and service requirements | Training, monitoring equipment and recurrent costs |
For a new Kenyan borehole, compare the survey, mobilisation, drilled metres, casing/screens, development, pumping test and laboratory analysis as distinct quantities. Then price the verified pump duty, power, storage, treatment and pipe route. Our planning calculator is an initial estimate; a complete quotation needs the actual site and inclusions. WRA’s permitting workflow distinguishes authorisation to construct works from the subsequent water-use permit.
Acceptance, records and the first month of operation
Healthcare handover requires more than demonstrating flow. The institution’s authorised clinical and technical representatives should review the agreed evidence and unresolved items before relying on the system for intended services.
- Retain the reviewed design, source reports and complete source-to-outlet commissioning records.
- Label equipment, sampling points and isolation arrangements consistently with the facility drawings.
- Document staff responsibilities, fault escalation and the approved contingency procedure.
- Schedule review after service changes and retain corrective-action records with routine monitoring.
Build the brief around the Kenyan site
Start with the facility level, services, existing water plan, source records and the responsible clinical and estates contacts. Use the linked technical guides to organise the groundwater work while maintaining separate specialist requirements.
- Hydrogeological survey and site assessment
- Pumping tests and operating evidence
- Water analysis and treatment planning
- Water plumbing and storage
- Nairobi research guide
- Kisumu research guide
- Institutional procurement and asset records
- Donor-funded healthcare infrastructure
Prepare a facility water project brief
Is potable borehole water suitable for dialysis or sterilisation?
That cannot be assumed. Specialist clinical uses require their own specifications, treatment, verification and oversight by the responsible qualified teams. This guide does not provide those specifications.
Can a standard clinic drawing be used for any hospital?
No. The cited Kenyan report is conceptual and explicitly concerns Level 2 and Level 3 facilities. Larger or different services require a design suited to their actual functions.
What proves the system is ready for use?
Readiness depends on the facility-approved acceptance plan, verified quality and delivery conditions, trained staff and documented operating and contingency arrangements. A drilling invoice or water-flow demonstration is insufficient.
Sources, applicability and remaining checks
- WASH FIT, second edition — World Health Organization and UNICEF, 2022-04-25.
- Infrastructure Design and Construction Quality for WASH in Health Care Facilities: Basic Design Report — Kenya Ministry of Water, Sanitation and Irrigation; K-WASH, 2025-11.
This is project-brief guidance, not clinical advice, a healthcare certification or a specialist water design. The published November 2025 Basic Design Report has a Level 2/3 conceptual scope; a separate document labelled DRAFT is not treated as enacted requirements. Clinical norms, reserve durations and specialist treatment parameters are deliberately not invented.